Most recent

ISO 16889:2022

Hydraulic fluid power - Filters - Multi-pass method for evaluating filtration performance of a filter element


This document describes the following:

 

—    a multi-pass filtration performance test with continuous contaminant injection for hydraulic fluid power filter elements;

 

NOTE 1   For the background interlaboratory study used to verify the test methodology, see Annex D.

 

—    a procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics;

 

—    a test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes  25 µm(c), and a final reservoir gravimetric level of less than 200 mg/L;

 

NOTE 2   It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.

 

—    a test using ISO medium test dust (ISO MTD) contaminant and a test fluid in accordance with Annex A.

 

This document is intended to provide a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.

 

This document applies to three test conditions:

 

—    test condition 1, with a base upstream gravimetric level of 3 mg/L;

 

—    test condition 2, with a base upstream gravimetric level of 10 mg/L;

 

—    test condition 3, with a base upstream gravimetric level of 15 mg/L.


CONTENT PROVIDER
International Organization for Standardization [iso]

Others Also Bought
Hydraulic fluid power - Filters - Evaluation of differential pressure versus flow
Bubble-Point Test Method
Hydraulic fluid power - Filter elements - Verification of collapse/burst pressure rating
Document History
Revises:
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.